This is more of an indicator light than anything else.
Aqua rite chlorine generator inspect cell.
How to reset inspect cell light.
I have an aqua trol since 2011.
Your chlorine generator is still producing chlorine at the moment which is a good thing.
Just like any other salt chlorine generator the aqua rite may need a quick tune up from time to time.
Aqua rite chlorine generator cele turbo cell control electronics hayward.
I have repaired the thermister several times over the years and replaced the lcd display board.
The hayward aqua rite salt chlorine generator is hands down the most popular residential salt chlorinator in the pool industry.
The 1 salt cell is also the best value saving 50 or more over conventional chlorine.
The check salt inspect cell led s flash together when.
T 15 is the factory default.
I have a older 2001 aqua rite chlorine generator with tcell 15.
I guess the cell is dead.
To manually reset the inspect cell led press and hold the diagnostics button until led goes out approximately 3 to 5.
Using information provided by hayward pool we have created the following troubleshooting guide to help pool owners understand the diagnostic codes and quickly.
How to set turbo cell type before operation the aqua rite must be configured for the chlorinator cell that will be used.
Chlorine production is halted.
It shows inspect cell and salt level illuminated steady.
Nsf tested and proven genuine hayward turbocells have reliably delivered chlorine for nearly two decades.
It always stays at 1600.
The check salt inspect cell led s will stay on when.
Producing enough chlorine for pools up to 15 000 gallons.
Aqua rite salt chlorinator has a built in reminder to inspect and clean the cell every 500 hrs.
If the check salt light is lit on a hayward aqua rite salt chlorinator it could mean a number of things.
Your salt level is between 2500 2600 parts per million ppm.
First check the display salt reading if it s 2 700 ppm or lower the check salt light will come on.
Check salt inspect cell led s will be on when salt level is 2300ppm or less.